Healthy Air Inc.

HealthyAir Nail Salon Source Capture Ventilation | Single Station

$1,295.00
Color: White
Hose Length & Hood: 4'L - Rectangular
LED: No LED
HealthyAir Source Capture System 
Single Station Exhauster to Vent to Outside

 

Protect Your Breathing Zone with Source Capture® Technology

The HealthyAir® Source Capture® Fan-Filter Exhauster Single Station system is engineered to extract airborne particulate and dust from the breathing zone to improve indoor air quality and reduce occupational hazard risks.

This unit is ideal for outside ventilation applications that require exhausting out of the facility by connecting the outlet of the unit to an exhaust duct (if required by local commercial building and mechanical code).

This unit is engineered to provide ventilation for one workstation. 


Nail Salon Application

(1) HealthyAir® Source Capture® Fan-Filter Exhauster Single Station system is engineered to ventilate (1) nail station (manicure or pedicure).

 

Nail Salon IMC Ventilation Code Compliance

The HealthyAir® Source Capture® Fan-Filter Exhauster fully complies with, and exceeds, IMC Ventilation Code requirements for Nail Salons. 

For Nail Salons IMC Chapter 4 mechanical code generally requires:

  • a minimum of 50 cfm of air extraction from each nail station
  • at least one exhaust inlet per nail station located <12” from the point of chemical application
  • exhaust of all extracted air from the nail salon to the outdoor atmosphere

 

 Added benefits of system use include:

  • The clean air output of each system can be applied to the total 0.6 cfm/ft2 that is required to be exhausted from overall salon air, which in turn conserves energy
  • Prevents contaminated air from re-entering the salon and/or entering adjacent environments, including neighboring businesses or residences
  • Prevents nail dust from accumulating in duct work and creating potential hazards

 

IMC 2021 Ventilation Code: https://codes.iccsafe.org/content/IMC2021P1/chapter-4-ventilation

  

Outside Ventilation – IMC Ventilation Code Compliance

The HA-SCE-G2 model is primarily designed for use as an Outside Ventilation unit, whereby the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 5” dia. outlet port of the unit.

The components required to setup the unit for Outside Venting come with the unit, as outlined in the manual.

 

Weight, Dimensions & Installation

The approximate weight and base dimensions of the unit is: 40 lbs. - 12”l x 14”w x 21”h

The standard unit is equipped with (1) Extraction Hose; (1) 4'L or (1) 6'L.  Custom length hose is available, for information and pricing please contact us.

This portable floor unit is designed to be positioned in close proximity to the work station, however in some cases remote location of units is required. For customized layouts, please contact us for engineering and design recommendations.

 

Operation

By easily adjusting the flexible hose, the hoods of the extraction arms can be strategically positioned, approximately 6”-12” from the work area, to capture contaminates from the emission source.

The HA-SCE-G2 offers simple remote-control operation and is equipped with a three-speed fan that enables control of air flow and sound level.

Maintenance of the unit is simple and does not require the use of any tools.

 

Filter Model & Replacement

The HealthyAir® Source Capture® Fan-Filter Exhauster utilizes the model HA-FFM-Filter.  Each unit comes with (1) pre-installed filter.

The recommend filter replacement cycle is 18 months on average.  However, the need for filter replacement naturally varies depending on the frequency and nature of use.

When the unit has been in operation for 400-hours, the Filter Change indicator light, on the Control Panel, will begin to flash. This serves as a reminder to inspect and/or replace the filter.

The Filter Change Timer can be reset by following the reset protocol outlined in the manual.

The following replacement filter is compatible with this unit:

 

    Model Number
    HA-SCE-G2-S
    Air Flow (Max Total at Inlet)
    155 cfm
    Fan Air Flow (Free Flow)
    1060 cfm @ 3000 rpm
    Static Pressure (at Exhaust outlet port)
    0.25" WC
    Hose Length (Standard)
    4'L (Length options and custom length available)
    Weight
    37 lbs
    Base Dimensions
    14x12x24 in
    Rated Voltage
    120V/60Hz
    Amperage
    2.75A
    Power Consumption
    280W
    Shipping Policy

    Orders are typically shipped within 1-2 business days.  Order placed before 12:00pm EST often ship the same day.

    Orders are not shipped or delivered on weekends or holidays.

    1-Year Warranty

    Healthy Air Inc. only makes this 1-Year Warranty to the original retail purchaser who submits the enclosed Warranty Registration Card within 10 days of purchase by email to Orders@HealthyAir.com.

    Click here for full details.

    Color: White
    Hose Length & Hood
    LED

    Protect Your Breathing Zone with Source Capture & Local Exhaust Ventilation

    HealthyAir Source Capture Systems are engineered to extract airborne contaminants from the breathing zone to improve indoor air quality and reduce occupational hazard risks.

    The Single Station Source Capture Fan-Filter Exhauster is designed to provide ventilation for one technician/workstation.

    This unit can be operated as a free-standing portable Source Capture Dust Collector unit (with caster wheels installed) or fixed in place and connected to an exhaust duct to vent outside (if required by local commercial building and mechanical code - i.e. IMC code for nail salons outside ventilation compliance).

    Recirculating vs. Outside Ventilation

    The HealthyAir Source Capture Exhauster System can operate as a Recirculating Ventilation (Dust Collector) or Outside Ventilation (Local Exhauster Ventilation) system depending on how it is configured for use.

    The out-of-the-box default mode of operation is Recirculating Ventilation, and every unit comes with the components require to reconfigure the unit for Outside Ventilation.

    Recirculating Ventilation - Dust Collector

    Recirculating Ventilation means the unit is designed to take in contaminated air though the extraction hose, filter dust and particulate, and discharge filtered air from the exhaust vent, located on the bottom of the unit, back into the facility.

     

    Outside Ventilation

    The components required to setup the unit for Outside Venting come with the unit, as outlined in the manual. When configured for Outside Ventilation, the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 4” dia. outlet port of the unit.

    Operation of Single Station Dust Collector Exhauster System

    The Single Station Source Capture Exhauster is a Fan-Filter Dust Collector designed to provide ventilation for one workstation.

    This unit can be operated as a free-standing portable Dust Collector System, with the caster wheels installed, or it can be set in a fixed floor position and connected to an exhaust duct for local exhaust outside ventilation (if required by local commercial building and mechanical code).

    Once the unit is set in the desired location, the hood (air inlet) of the extraction arm can be strategically positioned approximately 6”-12” from the work area, by easily adjusting the flexible hose, to capture contaminates from the emission source.

    The units offers simple remote-control operation and is equipped with a three-speed fan that enables control of air flow.

    Maintenance of the unit is simple and does not require the use of any tools.

    Filter Model & Replacement

    The Healthy Air Single Station Source Capture Exhauster utilizes the HA-FFM-1111 Fan-Filter Module. Each unit comes with pre-installed filter.

    The recommend filter replacement cycle is 9 months on average. However, the need for filter replacement naturally varies depending on the frequency and nature of use.

    When the unit has been in operation for 1,000-hours, the Filter Change indicator light, on the Control Panel, will begin to flash. This serves as a reminder to inspect and/or replace the filter.

    The Filter Change Timer can be reset by following the reset protocol outlined in the manual.

    Technical Specifications

    Download Specification Sheet with complete product dimensions and air flow rate information.

    Setup & "Installation"

    This floor unit is designed for use as a portable or fixed unit, positioned in close proximity to the work station.

    In some cases remote location of units is required. For customized layouts, please contact us for engineering and design recommendations.

    Initial setup of the unit for portable recirculating ventilation operation is simple and only requires connection of the extraction hose and caster wheels.  The caster wheels enable the unit to be easily moved as needed.

    Connection of Unit Outlet to Exhaust Duct for Outside Ventilation

    The HealthyAir Source Capture System provides a 5" dia. exhaust outlet port for connection of the unit to the exhaust duct.

    To connect the unit to an exhaust duct for outside ventilation, a local HVAC technician, plumber, general contractor or DIY enthusiast is required to install the exhaust ducting that will connect to the exhaust outlet port of the unit.

    Depending on user preference and site considerations, there are several options for the exhaust duct material, including galvanized sheet metal duct, PVC, aluminum flex duct or other flexible material for direct connection to the unit's outlet port and the exhaust line that vents out of the facility.

    The option of utilizing our specialized Exhaust Duct Flex Hose as a transition for connection of the unit to the main exhaust duct is also available.  This component is provided as a separate item that can be added, and various lengths are available to choose from.

    • Model Number = HA-SCE-G2-S
    • Air Flow (Max Total at Inlet) = 155 cfm
    • Fan Air Flow (Free Flow) = 1060 cfm @ 3000 rpm
    • Static Pressure (at Exhaust outlet port) = 0.25" WC
    • Hose Length (Standard) = 4'L (Length options and custom length available)
    • Weight = 37 lbs
    • Base Dimensions =14x12x24 in
    • Rated Voltage = 120V/60Hz
    • Amperage = 2.75A
    • Power Consumption = 280W
    Patented eHEPA®

    Proven electrostatic HEPA filtration for superior performance and extended filter life.

    Design to Meet IMC

    Complies with Chapter 4 & 5 International Mechanical Codes for source capture, ventilation and exhaust.

    Financing Available

    Flexible payment options to make clean air more accessible for your business.

    Free US Shipping

    Fast, free delivery anywhere in the continental United States.