Healthy Air Inc.

HealthyAir Nail Salon Source Capture Air Purifier | Single Station

$1,825.00
Color: White
Hose Length & Hood: 4'L - Rectangular
LED: No LED
HealthyAir Source Capture System Air Purifier
Single Station

 

3-In-1 Specialized Source Capture Air Purifiers that Effectively Reduce Occupational Health Hazards and Improve Indoor Air Quality

  1. Activated Carbon Air Purifier = Captures Chemical Fumes (VOCs)
  2. Air sanitizer = Kills microorganisms (bacteria, virus, mold and fungi)
  3. Dust Collector = Collects Ultra Fine-Particles (PM2.5)

 

 

Protect Your Breathing Zone with Source Capture® eHEPA® Technology

The HealthyAir® Source Capture® Air Purifier Single Station system is engineered to extract airborne contaminants from the breathing zone to improve indoor air quality and reduce occupational hazard risks.

This unit is engineered to provide ventilation for one workstation. 

This unit can be operated as a free-standing portable unit or connect to an exhaust duct to vent outside (if required by local commercial building and mechanical code)

 

Nail Salon Application

(1) HealthyAir® Source Capture® Dual Station system is engineered to ventilate (1) nail station (manicure or pedicure).

 

Nail Salon IMC Ventilation Code Compliance

All HealthyAir® Source Capture® system fully comply with, and exceed, IMC Ventilation Code requirements for Nail Salons.

 

For Nail Salons IMC Chapter 4 mechanical code generally requires:

  • a minimum of 50 cfm of air extraction from each nail station
  • at least one exhaust inlet per nail station located <12” from the point of chemical application
  • exhaust of all extracted air from the nail salon to the outdoor atmosphere

 

Added benefits of system use include:

  • The clean air output of each system can be applied to the total 0.6 cfm/ft2 that is required to be exhausted from overall salon air, which in turn conserves energy
  • Prevents contaminated air from re-entering the salon and/or entering adjacent environments, including neighboring businesses or residences
  • Prevents nail dust from accumulating in ductwork and creating potential hazards

 

IMC 2021 Ventilation Code: https://codes.iccsafe.org/content/IMC2021P1/chapter-4-ventilation

 

Patented eHEPA® Technology

With patented eHEPA® technology, this unit effectively filter air in a highly efficient and innovative 3-stage process, resulting in a safer work environment with a healthier breathing zone for occupants.

As contaminated air passes through the unit, the Pre-Filter, eHEPA® Filter, and Enhanced Carbon Catalytic Filter work in conjunction to collect and deactivate airborne particles; including dust, smoke, allergens, gasses, odors, and VOCs.

HealthyAir® System 3-stage process collectively utilizes the 5 filtration methods of Sieving, Direct impact, Inertial Impaction, Diffusion, and Electrostatic. 

 

Recirculating Ventilation

The Healthy Air® Source Capture® Air Purifier may be operated as a Recirculating System or as an Outside Venting System.  The out-of-the-box default configuration of the unit is for Recirculating Ventilation.

Recirculating Ventilation means the unit is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge purified air from the exhaust vent, located on the bottom of the unit, back into the facility.

 

Outside Ventilation – IMC Ventilation Code Compliance

The components required to setup the unit for Outside Venting come with the unit, as outlined in the manual. When configured for Outside Ventilation, the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 4” dia. outlet port of the unit.

 

Weight, Dimensions & Installation

The approximate weight and base dimensions of the unit is: 45 lbs. - 12”l x 14”w x 21”h

The standard extraction arm hose length is 4'.  Custom length hose is available, for information and pricing please contact us.

This portable floor unit is designed to be positioned in close proximity to the work station, however in some cases remote location of units is required. For customized layouts, please contact us for engineering and design recommendations.

Initial setup of the unit is simple and requires installation of the extraction hose and caster wheels.  The caster wheels enable the unit to be easily moved as needed.

 

Operation

By easily adjusting the flexible hose, the hoods of the extraction arms can be strategically positioned, approximately 6”-12” from the work area, to capture contaminates from the emission source.

The HA-SCP-G4 and HA-SCP-G5 units offers simple remote-control operation and is equipped with a three-speed fan that enables control of air flow.

Maintenance of the unit is simple and does not require the use of any tools.

 

Filter Model & Replacement

The Healthy Air® Source Capture Air Purification System utilizes the HA-IFM-1111 Integrated Filter Module.  Each unit comes with (1) pre-installed filter.

The recommend filter replacement cycle is 6 months on average.  However, the need for filter replacement naturally varies depending on the frequency and nature of use.

When the unit has been in operation for 400-hours, the Filter Change indicator light, on the Control Panel, will begin to flash. This serves as a reminder to inspect and/or replace the filter.

The Filter Change Timer can be reset by following the reset protocol outlined in the manual.

The following replacement filter is compatible with this unit:

 

 

 

Model Number
HA-SCP-G6-S
Air Flow (Max Total at Inlet)
155 cfm
Fan Air Flow (Free Flow)
1060 cfm @ 3000 rpm
Static Pressure (at Exhaust outlet port)
0.25" WC
Hose Length (Standard)
4'L (Length options and custom length available)
Weight
40 lbs
Base Dimensions
14x12x24 in
Rated Voltage
120V/60HZ
Amperage
2.75A
Power Consumption
280W
Shipping Policy

Orders are typically shipped within 1-2 business days.  Order placed before 12:00pm EST often ship the same day.

Orders are not shipped or delivered on weekends or holidays.

1-Year Warranty

Healthy Air Inc. only makes this 1-Year Warranty to the original retail purchaser who submits the enclosed Warranty Registration Card within 10 days of purchase by email to Orders@HealthyAir.com.

Click here for full details.

Color: White
Hose Length & Hood
LED

Protect Your Breathing Zone with eHEPA® Source Capture® Technology

The HealthyAir® Source Capture Systems® are engineered to extract airborne contaminants from the breathing zone to improve indoor air quality and reduce occupational hazard risks.

The Single Station Source Capture® Air Purifier unit is designed to provide ventilation for one technician/workstation.

This unit can be operated as a free-standing portable unit (with caster wheels installed) or fixed in place and connected to an exhaust duct to vent outside (if required by local commercial building and mechanical code)

Patented HealthyAir® eHEPA® Technology

With patented eHEPA® technology, this unit effectively filter air in a highly efficient and innovative 3-stage process, resulting in a safer work environment with a healthier breathing zone for occupants.

As contaminated air passes through the unit, the Pre-Filter, eHEPA® Filter, and Enhanced Carbon Catalytic Filter work in conjunction to collect and deactivate airborne particles; including dust, smoke, allergens, gasses, odors, and VOCs.

HealthyAir® System 3-stage process collectively utilizes the 5 filtration methods of Sieving, Direct impact, Inertial Impaction, Diffusion, and Electrostatic. 

Recirculating vs. Outside Ventilation

Every HealthyAir® Source Capture System® can operate as a Recirculating Ventilation or Outside Ventilation system depending on how it is configured for use.

The out-of-the-box default mode of operation is Recirculating Ventilation, and every unit comes with the components require to reconfigure the unit for Outside Ventilation.

Recirculating Ventilation

Recirculating Ventilation means the unit is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge purified air from the exhaust vent, located on the bottom of the unit, back into the facility.

 

Outside Ventilation

The components required to setup the unit for Outside Venting come with the unit, as outlined in the manual. When configured for Outside Ventilation, the system is designed to take in contaminated air though the extraction hose, filter contaminants, and discharge treated air out of the facility via an exhaust duct connection to the 4” dia. outlet port of the unit.

Operation of Single Station System

The Single Station Source Capture® Air Purifier is designed to provide ventilation for one workstation.

This unit can be operated as a free-standing portable unit, with the caster wheels installed, or it can be set in a fixed location and connected to an exhaust duct to vent outside (if required by local commercial building and mechanical code).

Once the unit is set in the desired location, the hood (air inlet) of the extraction arm can be strategically positioned approximately 6”-12” from the work area, by easily adjusting the flexible hose, to capture contaminates from the emission source.

The HA-SCP-G5-S and HA-SCP-G6-S units offers simple remote-control operation and is equipped with a three-speed fan that enables control of air flow.

Maintenance of the unit is simple and does not require the use of any tools.

Filter Model & Replacement

The Healthy Air® Source Capture Air Purification System utilizes the HA-IFM-1111 Integrated Filter Module. Each unit comes with pre-installed filter.

The recommend filter replacement cycle is 6 months on average. However, the need for filter replacement naturally varies depending on the frequency and nature of use.

When the unit has been in operation for 400-hours, the Filter Change indicator light, on the Control Panel, will begin to flash. This serves as a reminder to inspect and/or replace the filter.

The Filter Change Timer can be reset by following the reset protocol outlined in the manual.

Nail Salon IMC Ventilation Code Compliance

All HealthyAir® Source Capture® system fully comply with, and exceed, IMC Ventilation Code requirements for Nail Salons. To meet Mechanical Code for Nail Salons, a HealthyAir® Source Capture System® must be configured for outside ventilation per the requirements of the building department.

 

For Nail Salons IMC Chapter 4 mechanical code generally requires:

  • a minimum of 50 cfm of air extraction from each nail station
  • at least one exhaust inlet per nail station located <12” from the point of chemical application
  • exhaust of all extracted air from the nail salon to the outdoor atmosphere

 

Added benefits of system use include:

  • The clean air output of each system can be applied to the total 0.6 cfm/ft2 that is required to be exhausted from overall salon air, which in turn conserves energy
  • Prevents contaminated air from re-entering the salon and/or entering adjacent environments, including neighboring businesses or residences
  • Prevents nail dust from accumulating in ductwork and creating potential hazards

 

IMC 2021 Ventilation Code: https://codes.iccsafe.org/content/IMC2021P1/chapter-4-ventilation

Technical Specifications

Download Specification Sheet with complete product dimensions and air flow rate information.

Setup & "Installation"

This floor unit is designed for use as a portable or fixed unit, positioned in close proximity to the work station.

In some cases remote location of units is required. For customized layouts, please contact us for engineering and design recommendations.

Initial setup of the unit for portable recirculating ventilation operation is simple and only requires connection of the extraction hose and caster wheels.  The caster wheels enable the unit to be easily moved as needed.

To connect the unit to an exhaust duct for outside ventilation, a local HVAC technician, plumber, or general contractor is required to simply install the exhaust ducting that will connect to the exhaust (outlet) port of the unit.

  • Model Number = HA-SCP-G6-S
  • Air Flow (Max Total at Inlet) = 155 cfm
  • Fan Air Flow (Free Flow) = 1060 cfm @ 3000 rpm
  • Static Pressure (at Exhaust outlet port) = 0.25" WC
  • Hose Length (Standard) = 4'L (Length options and custom length available)
  • Weight = 40 lbs
  • Base Dimensions =14x12x24 in
  • Rated Voltage = 120V/60HZ
  • Amperage = 2.75A
  • Power Consumption = 280W
Patented eHEPA®

Proven electrostatic HEPA filtration for superior performance and extended filter life.

Design to Meet IMC

Complies with Chapter 4 & 5 International Mechanical Codes for source capture, ventilation and exhaust.

Financing Available

Flexible payment options to make clean air more accessible for your business.

Free US Shipping

Fast, free delivery anywhere in the continental United States.